HANNA HI98194 Multiparameter

Specificaitons:
pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH
pH Calibration automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
mV Range ±600.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.5 mV
ORP Range ±2000.0 mV
ORP Resolution 0.1 mV
ORP Accuracy ±1.0 mV
ORP Calibration automatic at one custom point (relative mV)
EC Range 0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC up to 400.0 mS/cm)
EC Resolution auto-ranging: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 µS/cm; 0.001 mS/cm; 0.01
EC Accuracy ±1% of reading or ±1 µS/cm whichever is greater
EC Calibration automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range 0 to 9999 ppm (mg/L); 0.000 to 400.0 ppt (g/L) (maximum value depends on TDS factor)
TDS Resolution manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt):
TDS Accuracy ±1% of reading or ±1 ppm (mg/L), whichever is greater
TDS Calibration based on conductivity calibration
Resistivity Range 0 to 999999 ?•cm; 0 to 1000.0 k?•cm; 0 to 1.0000 M?•cm
Resistivity Resolution dependent on resistivity reading
Resistivity Calibration based on conductivity calibration
Salinity Range 0.00 to 70.00 PSU
Salinity Resolution 0.01 PSU
Salinity Accuracy ±2% of reading or ±0.01 PSU whichever is greater
Salinity Calibration based on conductivity calibration
Seawater ? Range 0.0 to 50.0 ?t, ??, ???
Seawater ? Resolution 0.1 ?t, ??, ???
Seawater ? Accuracy ±1 ?t, ??, ???
Seawater ? Calibration based on conductivity calibration
DO Range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
DO Resolution 0.1%; 0.01 ppm (mg/L)
DO Accuracy 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading
DO Calibration automatic one or two points at 0 and 100% or one custom point
Atmospheric Pressure Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric Pressure Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric Pressure Accuracy ±3 mm Hg within ±15°C from the temperature during calibration
Atmospheric Pressure Calibration automatic at one custom point
Temperature Range -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K
Temperature Resolution 0.01 K, 0.01 °C, 0.01 °F
Temperature Accuracy ±0.15 °C; ±0.27 °F; ±0.15 K
Temperature Calibration automatic at one custom point
Temperature Compensation automatic from -5 to 55 °C (23 to 131 °F)
Logging Memory 45,000 records (continuous logging or log-on-demand of all parameters)
Logging Interval one second to three hours
PC Connectivity USB to PC with HI9298194 Hanna software installed
Battery Type/Life 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight). With probe connected, approximately 104 hours of continuous use without backlight.
Environment 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight 400 g (14.2 oz.)
Ordering Information HI98194 is supplied with HI7698194 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.

📞 WhatsApp0813-8223-8643

📧 Emailsahabatteknikindometer@gmail.com

Deskripsi

HI98194 Multiparameter: Solusi Monitoring Air Terbaik

Fungsi Produk HI98194 Multiparameter

HI98194 Multiparameter merupakan alat ukur air portabel yang dirancang untuk memantau berbagai parameter kualitas air secara akurat dan efisien. Alat ini mampu mengukur hingga 12 parameter utama seperti pH, suhu, oksigen terlarut (DO), konduktivitas, dan banyak lagi. Sangat cocok digunakan dalam aplikasi lingkungan, industri, dan laboratorium, menjadikan HI98194 sebagai solusi terpadu untuk monitoring air yang membutuhkan akurasi tinggi.

Keunggulan Produk HI98194 Multiparameter

Salah satu keunggulan utama HI98194 adalah desainnya yang kokoh dan tahan air, dengan rating IP67 yang memastikan seluruh perangkat terlindungi dari kondisi lingkungan ekstrem. Layar LCD berwarna memudahkan navigasi dan pembacaan hasil di berbagai kondisi pencahayaan. Dengan teknologi Quick Cal, proses kalibrasi menjadi lebih cepat dan akurat. Selain itu, sensor elektroda yang modular dapat diganti dengan mudah, sehingga penggunaan alat ini lebih fleksibel dan ekonomis. Alat ini juga mendukung log data hingga 45,000 sampel, memberikan kemampuan pelacakan data jangka panjang untuk analisis yang lebih mendalam.

Cara Penggunaan HI98194 Multiparameter

Penggunaan HI98194 sangat sederhana, bahkan bagi pemula. Langkah pertama adalah memastikan semua sensor telah terhubung dan dikalibrasi sesuai petunjuk manual. Setelah itu, cukup celupkan elektroda ke dalam air yang ingin diuji, dan hasilnya akan ditampilkan secara real-time di layar. Hasil pengukuran dapat disimpan langsung ke alat untuk diakses nanti atau ditransfer melalui USB ke perangkat lain untuk analisis lebih lanjut. Pastikan alat dibersihkan secara teratur untuk menjaga performa optimal dan keakuratan hasil pengukuran.

Ulasan

Belum ada ulasan.

Jadilah yang pertama memberikan ulasan “HANNA HI98194 Multiparameter”

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *