HANNA HI98197 Ultra Pure Water EC/Resistivity

High purity water used in power generation, semiconductor manufacturing and other industries can be difficult to measure can be difficult to measure due the ability of carbon dioxide (CO2) to diffuse into water and forming carbonic acid (H2CO3). The carbonic acid will dissociate into hydrogen ions (H+) and bicarbonate ions (HCO3). These ions will increase the conductivity and decrease the resistivity of the water. In order to measure high purity water accurately it is necessary to perform a continuous flow measurement. The HI98197 uses the HI763123 four ring probe with a threaded connection that is screwed into a stainless steel body flow cell. The flow cell is connected to a water source to determine the conductivity or resistivity whichever is preferred. The HI98197 is an ideal meter for monitoring the mixed bed resin or equivalent system that produces high purity water of 18.2 MΩ * cm at 25 °C.

 

Expanded Ranges – HI98197 has an expanded conductivity range from 0.000 μS/cm to 1000 mS/cm actual conductivity (400 mS/cm temperature compensated). The HI98197 also has ranges for TDS, resistivity and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows the user to adjust the nominal cell constant.

USP <645> – HI98197 can be used to perform all three stages of USP <645> method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.

5-Point Calibration – Calibration can be performed up to five points with seven preprogrammed conductivity standards. For salinity (% NaCl range), HI7037 standard allows users to perform a one-point calibration.

Temperature Compensation – EC and TDS measurements are fully customizable and include: cell constant selection between 0.0 and 10.000 and a selection of linear, non-linear (natural water) or no temperature compensation. The temperature compensation coefficient range is configurable from 0.00 to 10.00%/°C with a choice of reference temperatures of 15°C, 20°C and 25°C.

TDS Conversion Factor – The conductivity to TDS factor is adjustable from 0.40 and 1.00.

User Profiles – The HI98197 allows for the creation of 10 measurement profiles with various user settings including temperature compensation, range selection, cell constant, and TDS conversion factors.

Logging – The log-on-demand mode allows the user to record and save up to 400 readings while the lot logging at selected intervals can store up to 1000 readings.  This data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.

Good Laboratory Practice (GLP) – GLP data includes date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS) is directly accessible by pressing the dedicated GLP key.

Contextual Help – Access Help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed.

Graphic LCD – The high contrast graphic LCD is easy to read outdoors in bright sunlight as well as in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.

Thermoformed Carrying Case – The compact, durable HI720197 carry case is thermoformed to hold all necessary components for taking a field measurement, including the meter and probe, beakers and conductivity standards.

📞 WhatsApp0813-8223-8643

📧 Emailsahabatteknikindometer@gmail.com

Deskripsi

HI98197 Ultra Pure Water EC/Resistivity

HI98197: Alat Presisi untuk Pengukuran Ultra Pure Water

HI98197 Ultra Pure Water EC/Resistivity adalah perangkat canggih yang dirancang khusus untuk membantu Anda mengukur kualitas air ultrapure dengan akurasi tinggi. Berkat teknologi mutakhirnya, alat ini mampu memberikan hasil yang presisi, sehingga ideal untuk kebutuhan laboratorium, penelitian, dan industri yang membutuhkan kontrol air ultrapure berkualitas tinggi.

Keunggulan HI98197

HI98197 menawarkan berbagai keunggulan yang membuatnya unggul dalam kategori perangkat pengukur elektrokonduktivitas (EC) dan resistivitas:

– Presisi Tinggi: Menggunakan sensor canggih, alat ini memastikan pengukuran yang akurat, bahkan pada nilai EC dan resistivitas yang sangat rendah.

– Kemudahan Penggunaan: Desain user-friendly dengan layar LCD yang jelas serta navigasi menu intuitif memudahkan pengguna dalam mengoperasikan alat.

– Kapasitas Multi-Pengukuran: HI98197 tidak hanya mengukur EC, tetapi juga resistivitas, TDS (Total Dissolved Solids), suhu, dan parameter lainnya dalam satu perangkat.

– Daya Tahan Tinggi: Dilengkapi dengan casing yang tahan lama, alat ini cocok digunakan dalam berbagai kondisi lingkungan dan mampu menghadapi tantangan di lapangan.

Cara Penggunaan HI98197

Menggunakan HI98197 sangatlah mudah, bahkan untuk pengguna pemula. Berikut langkah-langkah penggunaannya:

1. Persiapan Alat: Pastikan HI98197 telah diisi baterai dan sensor terhubung dengan benar.

2. Kalibrasi: Lakukan kalibrasi menggunakan larutan standar untuk memastikan akurasi maksimal. Proses ini bisa dilakukan dengan panduan otomatis yang tersedia di perangkat.

3. Pengukuran: Celupkan sensor ke dalam air ultrapure yang akan diuji. Tekan tombol pengukuran untuk mulai membaca parameter seperti EC, resistivitas, atau TDS.

4. Analisis Data: Hasil pengukuran akan muncul langsung di layar. Data tersebut dapat disimpan atau diunduh untuk analisis lebih lanjut.

Kesimpulan

HI98197 Ultra Pure Water EC/Resistivity adalah solusi terpercaya untuk kebutuhan evaluasi kualitas air ultrapure. Dengan keunggulan presisi tinggi, kemudahan penggunaan, serta desain yang tangguh, perangkat ini merupakan pilihan yang tepat bagi laboratorium dan industri yang mencari alat pengukur dengan performa unggul. Tingkatkan efisiensi kerja Anda dengan HI98197!

Ulasan

Belum ada ulasan.

Jadilah yang pertama memberikan ulasan “HANNA HI98197 Ultra Pure Water EC/Resistivity”

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *