HANNA HI98193 Portable Dissolved Oxygen and BOD Meter
The high contrast graphic LCD is easy to read outdoors in bright sunlight to low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.
The compact, durable HI760193 carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter and electrode, beakers, buffer solutions, cleaning solutions and storage solutions.
DO Range 0.00 to 50.00 ppm (mg/L); 0.0 to 600.0% saturation
DO Resolution 0.01 ppm (mg/L); 0.1% saturation
DO Accuracy ±1.5% of reading ±1 digit
DO Calibration automatic one or two point at 100% saturation (8.26 mg/L) and 0% saturation (0 mg/L).
Atmospheric Pressure Range 450 to 850 mmHg
Atmospheric Pressure Resolution 1 mmHg
Atmospheric Pressure Accuracy ± 3 mmHg within ±15% from the calibration point
Atmospheric Pressure Calibration one point at any in range pressure value
Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.2°C; ±0.4°F (excluding probe error)
Temperature Calibration one or two point at any in range temperature value
Temperature Compensation automatic from 0 to 50°C (32 to 122°F)
Measurement Modes direct DO; BOD (biochemical oxygen demand); OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate)
Barometric Compensation automatic from 450 to 850 mmHg
Salinity Compenstaion automatic from 0 to 70 g/L
Electrode/Probe HI764073 polarographic DO probe with protective sleeve, internal temperature sensor, DIN connector and 4m (13’) or 10m (32′) cable option will be provided.
Log-on-demand up to 400 samples
PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type/Life 1.5V AA batteries (4) / approximately 200 hours of continuous use without backlight (50 hours with backlight)
Auto-off user selectable: 5, 10, 30, 60 min or can be disabled
Environment 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight 400 g (14.2 oz.)
Ordering Information HI98193 is supplied with HI764073 DO probe, preformed PTFE membrane cap (2), HI7041S electrolyte solution (30 mL), HI7040 bicomponent zero oxygen solution, 100 mL plastic beakers (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, instrument quality certificate and HI760193 rugged carrying case.